Skip to the content
Menu
IBC-Dose Calibrator

COMECER

IBC-Dose Calibrator

The IBC DOSE CALIBRATOR is a completely digital dose calibrator with reading software. The ionisation chamber can be connected directly to a PC with Windows. The reading system and the control system are both managed by the IBC-LITE reading software.
The IBC DOSE CALIBRATOR is delivered with IBC-LITE Software (without PC) and Ionisation chamber (VIK-202 or VIK-203) aswell as a power supply for Ionisation chamber, a well liner and a sample holder.
Some of the important features are the GAMP-5 is validated, a built-in and preset isotope list. It is suitable for measuring vials and syringes aswell as user-definable containers. The DOSE CALIBRATOR has future dose calculation. The Quality control tests for the Ionisation chamber is run with the following activities:
Stability, linearity and null effect - Molybdenum breakthrough test -Background subtraction. The unit can print user-definable labels and has touch screen control.

Fully digitalIonization Chambers VIK-202 & VIK-203

The Ionization Chambers VIK-202 or VIK-203 all have a different read-out model. It can be interchanged or upgraded by using the same ionisation chamber.
All Dose Calibrators come standard with one well liner and one dipper, both designed and marked specifically for the VIK-202 Ionisation Chamber.

The Ionization Chambers VIK-202 (+/- 1% between 1 MBq and 200GBq) or VIK-203 (+/- 1% between 50 MBq and 700 GBq) is the measuring heart of each model dose calibrator. They have a fully digital detector that gives a fast and reliable read-out. The VIK-203 is available for a measurement range up to 20 Ci of F18 as an optional choise. The digital output enables flexible integration to detectors in other instruments or facilities. A feature which removes the need for a converter or separate read-out unit. The VIK-202 has a measurement range is up to 2 Ci of F18

VDC-606 Touch Screen Dose Calibrator

COMECER

VDC-606 Touch Screen Dose Calibrator

The VDC-606 Touch Screen Dose Calibrator is a touch-screen dose calibrator, which combines the best of both areas: it has the functionality of a software-based computer and it has the feauture of having the stability of a stand-alone unit.
The VDC-606 Touch Screen Dose Calibrator has the following standard accessories: An Ionization chamber (VIK-202 or VIK-203) a power supply and a IBC-LITE software + a well liner and a sample holder.

All VDC models operates together with the fully digital Ionisation Chamber VIK-202 or VIK-203. This VDC family concept, all have a different read-out model. It can be interchanged or upgraded by using the same ionisation chamber.
All Dose Calibrators come standard with one well liner and one dipper, both designed and marked specifically for the VIK-202 Ionisation Chamber.

Fully digitalIonization Chambers VIK-202 & VIK-203

The Ionization Chambers VIK-202 or VIK-203 is the measuring heart of each model dose calibrator. They have a fully digital detector that gives a fast and reliable read-out. The VIK-203 is available for a measurement range up to 20 Ci of F18 as an optional choise. The digital output enables flexible integration to detectors in other instruments or facilities. A feature which removes the need for a converter or separate read-out unit. The VIK-202 has a measurement range is up to 2 Ci of F18

VDC-603 Dose Calibrator

COMECER

VDC-603 Dose Calibrator

The VDC-603 dose Calibrator read-out is the plug & play basic model in the Dose Calibrator productline.
The standard supply that comes with the dose calibrator is the Ionisation chamber (VIK-202 or VIK-203), a reading unit, a well liner and a sample holder.

The accurate and reliable read-out of the ionisation chamber VIK-202 or VIK-203 is presented in a one-line, backlit display. This either by Becquerel or Curie which can be selected by the user. The product is suitable for all types of laboratory or hospital environments. Here being able to check the activity of a limited number of isotopes. This without the need for extensive, automatic quality control or labels printing.

All VDC models operates together with the fully digital Ionisation Chamber VIK-202 or VIK-203. This VDC family concept, all have a different read-out model. It can be interchanged or upgraded by using the same ionisation chamber.
All Dose Calibrators come standard with one well liner and one dipper, both designed and marked specifically for the VIK-202 Ionisation Chamber.

Fully digitalIonization Chambers VIK-202 & VIK-203

The Ionization Chambers VIK-202 or VIK-203 is the measuring heart of each model dose calibrator. They have a fully digital detector that gives a fast and reliable read-out. The VIK-203 is available for a measurement range up to 20 Ci of F18 as an optional choise. The digital output enables flexible integration to detectors in other instruments or facilities. A feature which removes the need for a converter or separate read-out unit. The VIK-202 has a measurement range is up to 2 Ci of F18.

CRC 55tW Dose Calibrator

CAPINTEC

CRC ® -55tW Dose Calibrator/Well Counter

The CRC®-55tR Dose Calibrator and Well Counter is a combined unit. This CRC®-55tW’s dose calibrator has advanced features with high speed and accuracy to measure activity and prepare doses. The CRC®-55tW´s ion chamber is time-tested and has a high pressure well designs. It is capable of measuring a dose as high as 6 Ci (250 GBq) with accuracy. The CRC®-55tW has a new helpful chamber plug-and-play capability.

In order to do the wipe testing, the CRC®-55tW makes it possible to define specific counting procedures (protocols) with levels of triggers to indentify work, patient, unrestricted areas and sealed source leak tests. The CRC®-55tW also has counting functions for wipe tests in as little as 6 seconds at activities as low as 1 nCi. In order to measure these Low activities it is done with a drilled well high sensitivity Sodium Iodide (NaI) detector.

To mention some of the features it would be: on screen display of Nuclide Name, Number, Activity, Unit of Measure and Calibration Number aswell as Large character, high visibility display.

The CRC®-55tW has over 80 Nuclides with half-lives in memory and a full alpha numeric touchpad. It has a built-in dose calibration, quality control and self diagnostics and an automated QC including constancy and linearity programs.

The dose Calibrator is compatible with Nuclear Medicine Management Systems via USB and it is possible to connect to an optional printer for full size NRC records and patient labels for syringes and vials. It has an automated Geometry and Linearity Testing aswell as it is capable of dual chambers. It supports exchange of chambers with the CRC®-55tPET dose calibrator with a chamber energy range: 15 keV to 3 MeV.

CRC 77tHR Dose Calibrator

CAPINTEC

CRC®-77tHR Dose Calibrator

The CRC®-77tHR’s performance and reliability is designed to meet the demanding needs of the high-activity isotope manufacturing and radiopharmaceutical production environment.

The Dose Calibrator's software is designed for rapid repeatable measurement functions, which is required in production. This also includes a fully automated Quality Assurance Program. The CRC®-77tHR hardware is designed to minimize the impact of high radiation fields upon electronics. As a feature it comes with a touch screen user interface securing a user friendly and efficient workflow.

The Dose Calibrator has a high activity range of up to 400 Curies for Tc-99m, USB/PC Communications, and pre-defined communication protocols for fast and easy system interface.

The CRC®-77tHR can be integrated with other products, which means that CRC-77tHR can be used within hot cell or hood environment.
The Dose Calibrator 77tHR has a maximum Activity of 400 Curies (15 TBq) and is made with a radiation resistant design. It comes with custom length liners and dippers available to match your hot cell dimensional requirements.

Operating functionality is with on screen display of Nuclide Name, Number, Activity, Unit of Measure and Calibration Number and 8” color VGA touch screen display. An other feature is built-in dose calibration, quality control and self-diagnostics. System wise it is compatible with Nuclear Medicine Management Systems via USB.

CRC OPT-4 Smart Dose Calibrator

CAPINTEC

CRC®-OPT-4 Smart Dose Calibrator

The CRC®-OPT-4 Smart Dose Calibrator system is a fully integrated network ready dose calibrator with an additionel management program which supports all functions nuclear in the areas of medicine and radiopharmacy.

The CRC®-PC Smart Dose Calibrator and Optility™ Management Software can both be displayed on the same large All-In-One touch screen PC. With this feature it will be the fastest and most user friendly operation available for processing orders, tracking inventory, measuring and dispensing doses, patient record-keeping, and regulatory compliance.

This Smart Dose Calibrator is network Ready with Remote Connectivity and can be displayed and viewed remotely within the Network.
It has a direct Interface to PC- no Readout Required aswell as a user adjustable threshold for Fastest Response.

The CRC®-OPT-4 Smart Dose Calibrator has the smallest Calibrator Footprint and has Ethernet Communications with software Upgrade via Ethernet Interface. The power is over Ethernet or USB port and the database stores QC, Moly and User Logs.

CRC 55tPET Dose Calibrator

CAPINTEC

CRC ® -55tPET Dose Calibrator

The CRC®-55tPET Dose Calibrator provides the industry’s best product. The CRC®-55tPET Dose Calibrator is designed with focus on accuracy and ease of operation. A reduced chamber pressure with increased bias voltage makes it possible to increase the maximum activity range for high energy PET isotopes.

Some of the main features of the 55tPET Dose Calibrator is a chamber plug-and-play capability, 28 programmable nuclide keys and a built-in dose calibration, quality control and self diagnostics. It has over 80 nuclides in memory aswell as an automatic chamber QC including linearity. The Dose Calibrator is via USB compatible with nuclear medicine information management systems.

It has 256 channel MCA with detailed spectrum for identification analysis. It is possible to make Lab tests include Schillings, Plasma and RBC volume. The dose calibrator has an automated well QC including Chi-Square and MDA aswell as manual and Automatic ROI.  It is possible to make different reports like: Well counter reports for autocalibration, system test, MDA, Chi-Square and laboratory tests are archived and searchable by date, type, land activity and automated Linearity Testing and Geometry Testing.

CRC 55tR Dose Calibrator

CAPINTEC

CRC ® -55tR Dose Calibrator

The 55tR Dose Calibrator generates the speed and accuracy to measure and prepare doses with the reliability and performance.

The -55tR is designed with a menu driven, color touch screen interface which is easy to operate and use. The ion chamber is time-tested with a high pressure chamber design, being able to measure a dose as high as 6 Ci (250 GBq) with high accuracy.

This dose calibrator has a single or optional second plug and play chamber capability and can be placed 100 feet from the readout unit.

The 55tR has a on screen display of Nuclide Name, Number, Activity, Unit of Measure and Calibration Number- with large character, high visibility display. It also provides over 80 Nuclides with half-lives in memory and has a full alpha numeric touchpad with a built-in dose calibration, quality control and self diagnostics.

The dose calibrator makes it possbile with an optional printer to make full size NRC records and patient labels for syringes and vials. It supports exchange of chambers and has a chamber energy range: 15 keV to 3 MeV.